Vista de página 267
5-20
TNC 416/TNC 406/TNC 306 List of machine parameters 3/2000
Machine
parameter
Function and input
Change
via
Reaction Page
MP7232 Enable Chinese Dialog
Entry range: 0 to 9
0 = Disable Chinese dialog
1 to 9 = Enable Chinese dialog
Character spacing in pixels
MP7240 PGM entry inhibited if PGM NR. same as OEM
cycle number
Entry values: 0 or 1
0 = Program entry inhibited
1 = Program entry not inhibited
123 9-3
MP7241 Inhibit the blocks ELCALL and WPCALL
Entry value: 0 or 1
0 = Soft keys inhibited
1 = Soft keys not inhibited
MP7245.0
MP7245.1
Inhibit the HEIDENHAIN standard cycles 1 to 15
Entry range: 0 to 65 535
0 = No cycle inhibited
Inhibit HEIDENHAIN cycles 16 to 31
Entry range: 0 to 65 535
0 = No cycle inhibited
4-86
4-86
MP7250 Difference between Q parameter numbers for
DLG DEF block and DLG CALL block in OEM cycle
Entry range: 0 to 50
9-3
MP7251 Number of global Q parameters transferred from
OEM cycle to calling program
Entry range: 0 to 100
10 = Q parameters Q90 to Q99 are global
(Q90 to Q99 are eroding parameters)