Heidenhain SHB Data Interfaces for HEIDENHAIN Manual do Utilizador Página 37

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 100
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 36
5 – 38 HEIDENHAIN Service Manual for Data Interfaces
EXT:
For adaptation of data transfer in standard data format and for blockwise transfer to peripheral
units.
Protocol: Standard protocol or blockwise transfer
Adaptation via machine parameters (from MP 5000)
Data format: Adaptation via machine parameters (from MP 5000)
Baud rate: 110 - 115 200 bauds
(depending on the hardware of the HEIDENHAIN product)
Interface parameters: Adaptation via machine parameters (from MP 5000)
Transfer stop: Software handshake with DC3 or hardware handshake with
RTS, selectable via machine parameters (from MP 5000)
LSV-2:
With the appropriate software (TNCremo V 3.0), the LSV-2 protocol allows various functions
such as file management, remote control, and diagnosis of the TNC to be executed from the PC.
Protocol: Bidirectional data transfer in accordance with DIN 66019
Data format: 8 data bits, 1 stop bit, no parity
Baud rate: 110 - 115 200 bauds
(depending on the hardware of the HEIDENHAIN product)
Interface parameters: Fixed
Transfer stop: Software handshake via protocol