Heidenhain PWM 8 Manual do Utilizador Página 49

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 90
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 48
- 49 -
Reference mark signal
Oscilloscope display x - t
Change the trigger setting of the oscilloscope basic setting
as follows:
Trigger channel A
Manual triggering (AC or DC)
Trigger negative edge
Traverse the reference mark to be checked
oscillatorily (forward/backward).
At the oscilloscope turn the trigger
potentiometer to set the trigger threshold
(LEVEL) such that the reference mark
signal is depicted as stationary image
on the screen.
Note:
Schematic display of Ue1+2 on the oscilloscope.
The actual amplitude is higher than displayed.
Vista de página 48
1 2 ... 44 45 46 47 48 49 50 51 52 53 54 ... 89 90

Comentários a estes Manuais

Sem comentários